Uma estratégia simplificada para a seleção da carga em testes de endurance de alta intensidade para avaliação de resposta terapêutica em pacientes com DPOC
dc.audience.educationlevel | Doutorado | |
dc.contributor.advisor | Nery, Luiz Eduardo [UNIFESP] | pt_BR |
dc.contributor.advisorLattes | http://lattes.cnpq.br/2605106957934146 | |
dc.contributor.author | Costa, Luiza Helena Degani [UNIFESP] | pt_BR |
dc.contributor.authorLattes | http://lattes.cnpq.br/0849899355881065 | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | pt_BR |
dc.coverage.spatial | São Paulo | |
dc.date.accessioned | 2020-03-25T12:10:51Z | |
dc.date.available | 2020-03-25T12:10:51Z | |
dc.date.issued | 2018-03-29 | |
dc.description.abstract | en | |
dc.description.abstract | O tempo de tolerância (Tlim) ao teste cardiopulmonar de carga constante (TCC) em cicloergômetro é uma variável sensível a intervenções terapêuticas em pacientes com DPOC. Embora uma diretriz recente da European Respiratory Society tenha recomendado que o Tlim pré-intervenção seja de 3 a 8 minutos (Tlim3’-8’), não há um método simples para selecionar a carga que deve ser aplicada para sistematicamente obtermos o Tlim dentro desta faixa. Nós avaliamos 59 pacientes com DPOC GOLD II-IV com o objetivo de testar uma estratégia pragmática de seleção da carga que possibilitasse a obtenção do Tlim3’-8’ e resultasse em testes reprodutíveis e sensíveis a intervenções. Todos os pacientes realizaram um TCC a 75% da carga de pico (TCC75%) do teste incremental prévio, até o limite da tolerância. Em caso de testes curtos (< 3 minutos, “baixa endurance”) ou longos (>8 minutos, “alta endurance”), os pacientes repetiam o teste após 1 hora com 50% ou 90% da carga de pico, respectivamente. Limitação ventilatória e dispneia intolerável ocorreram dentro da faixa de tempo recomendada com o TCC75% em 27 pacientes (45.7%, “endurance moderada”). Diminuindose ou aumentando-se a carga aplicada no TCC foi possível reduzir ou acelerar, respectivamente, a velocidade dos ajustes metabólicos e ventilatórios ao exercício. Desta forma, graus semelhantes de dispneia e limitação ventilatória foram alcançados entre 3 e 8 minutos em 5/6 pacientes de baixa endurance e 23/26 pacientes de alta endurance com o TCC50% e o TCC90%, respectivamente. De forma geral, o Tlim3’-8’ foi obtido em todos menos 4 pacientes (93.2%). Ajustes de carga menores (TCC60% nos pacientes de baixa endurance ou TCC80% nos de alta endurance) não permitiram obter o Tlim3’-8’ na maioria dos indivíduos. Repetindo-se os testes bem-sucedidos (TCC3’-8’) da estratégia TCC50%⇐75%⇒90% em um subgrupo (n=12) dos pacientes, observamos boa reprodutibilidade do Tlim após nebulização com placebo, com todos os testes mantendo-se dentro da faixa de duração desejada. A repetição dos testes após a nebulização com broncodilatadores nos mesmos pacientes, por sua vez, mostrou aumento mediano de 190 (30 – 365) s em relação ao Tlim basal. Em conclusão, a estratégia TCC50%⇐75%⇒90% levou sistematicamente a Tlim dentro da faixa recomendada de 3 a 8 minutos em mais de 90% dos pacientes com DPOC estudados, gerando testes reprodutíveis e sensíveis a intervenções terapêuticas. | pt_BR |
dc.description.abstract | Time to limitation (Tlim) in response to constant work rate (CWR) is sensitive to interventions in chronic obstructive pulmonary disease (COPD). Although a recent European Respiratory Society taskforce recommended a pre-intervention test lasting 3 to 8 min (Tlim3’-8’), there is no simple method to select a CWR consistently associated with Tlim3’-8’. The aims of the present study were to validate a pragmatic strategy to select a work rate (WR) associated with Tlim3’-8’, and to assess reproducibility and responsiveness of the resulting CWR3’-8’ test. We assessed 59 GOLD stages II – IV COPD patients, who initially cycled to Tlim at 75% peak (WRpeak). In case of short (< 3 min, low-endurance) or long (> 8 min, high-endurance) tests, patients exercised after 60 min at 50% or 90%, respectively. Critical mechanical constraints and limiting dyspnea at 75% were reached within the desired timeframe in 27 “mid-endurance” patients (45.7%). Decreasing or increasing CWR intensity slowed or hastened, respectively, the mechanicalventilatory responses; thus, similar physiological and sensory limits were reached at Tlim3’-8’ in 5/6 “low-endurance” and 23/26 “high-endurance” patients. Overall, Tlim3’-8’ was obtained in all but 4 patients (93.2%) with this CWR50%⇐75%⇒90% strategy. On the other hand, applying higher (60%) or lower (80%) WR intensities failed to consistently produce Tlim3’-8’ in “low-” and “high-endurance” subjects, respectively (p>0.05). Repeating CWR3’-8’ in a subgroup of patients (n=12) following nebulized placebo allowed to demonstrate that Tlim had good reproducibility, with endurance time remaining within the desired range in all subjects. Moreover, when the same patients repeated CWR3’-8’ following nebulized bronchodilators, there was a median (IQR) increase in Tlim of 190 (30 – 365) s (p < 0.05). This simplified approach to individualized work rate adjustment (CWR50%⇐75%⇒90%) successfully elicited critical mechanical constraints and limiting dyspnea within the time limits currently recommended in clinical trials in COPD (Tlim3’-8’), leading to tests that were reproducible and responsive to interventions. | en |
dc.description.source | Dados abertos - Sucupira - Teses e dissertações (2018) | pt_BR |
dc.format.extent | 79 f. | |
dc.identifier | https://sucupira.capes.gov.br/sucupira/public/consultas/coleta/trabalhoConclusao/viewTrabalhoConclusao.jsf?popup=true&id_trabalho=7347880 | pt |
dc.identifier.citation | COSTA, Luiza Helena Degani. Uma estratégia simplificada para a seleção da carga em testes de endurance de alta intensidade para avaliação de resposta terapêutica em pacientes com DPOC. 2018. Tese (Doutorado em Medicina: pneumologia) - Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, 2018. | pt_BR |
dc.identifier.file | 2018-0966.pdf | |
dc.identifier.uri | https://repositorio.unifesp.br/handle/11600/53021 | |
dc.language.iso | por | |
dc.publisher | Universidade Federal de São Paulo (UNIFESP) | pt_BR |
dc.rights | info:eu-repo/semantics/openAccess | pt_BR |
dc.subject | Copd | en |
dc.subject | Cardiopulmonary exercise testing | en |
dc.subject | Exercise endurance time | en |
dc.subject | Dpoc | pt_BR |
dc.subject | Teste de exercício cardiopulmonar | pt_BR |
dc.subject | Endurance | pt_BR |
dc.title | Uma estratégia simplificada para a seleção da carga em testes de endurance de alta intensidade para avaliação de resposta terapêutica em pacientes com DPOC | pt_BR |
dc.title.alternative | A simplified approach to select exercise endurance intensity for interventional studies in COPD | en |
dc.type | info:eu-repo/semantics/doctoralThesis | |
unifesp.campus | São Paulo, Escola Paulista de Medicina | pt_BR |
unifesp.graduateProgram | Medicina (Pneumologia) | pt_BR |
unifesp.knowledgeArea | Ciências da Saúde | pt_BR |
unifesp.researchArea | Fisiologia e Fisiopatologia Respiratória e do Exercício e Investigação do Risco Cirúrgico | pt_BR |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Luiza Helena Degani Costa PDFA.pdf
- Tamanho:
- 3.02 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- Tese de doutorado