Aplicabilidade de compensação matemática baseada em software na mudança de posição do paciente em exames de manometria esofágica perfusional

dc.contributor.advisorHerbella Fernandes, Fernando Augusto Mardiros [UNIFESP]
dc.contributor.advisor-coKatayama, Rafael Cauê [UNIFESP]
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/8333349236057831pt_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/4035568020554599pt_BR
dc.contributor.authorGualberto, Daniel Mello Moraes [UNIFESP]
dc.contributor.authorLatteshttp://lattes.cnpq.br/3373948200797341pt_BR
dc.coverage.spatialSão Paulopt_BR
dc.date.accessioned2024-01-31T18:38:20Z
dc.date.available2024-01-31T18:38:20Z
dc.date.issued2024
dc.description.abstractObjetivo: Validar um método de compensação matemática baseada em software das interferências causadas pela mudança de posição do paciente em exames de manometria esofágica perfusional. Métodos: O trabalho foi realizado em quatro etapas: a) modelagem física e matemática, b) implementação em software, c) testes ex-vivo e d) testes in-vivo. Em (a), foi construído um modelo teórico matemático do funcionamento de um equipamento perfusional, utilizando principalmente os conceitos da mecânica dos fluidos. Com base nas equações obtidas, foi proposto um método de compensação baseado em software das interferências geradas com a mudança de decúbito do paciente. Em (b), o método proposto foi efetivamente implementado em um software comercial para a realização de exames de manometria esofágica de alta resolução. Em (c), o software desenvolvido foi submetido a ensaios laboratoriais, e os resultados colhidos foram comparados aos previstos teoricamente. Em (d), foram realizados exames em cinco voluntários para verificar a usabilidade do software em condições reais. Resultados: Não foram encontradas diferenças significativas (p=0,3) entre os valores teóricos previstos em (a) e implementados em (b) e os obtidos experimentalmente em (c). Nos testes in vivo (d), a análise dos exames em ambas as posições pôde ser realizada normalmente, as interferências foram eliminadas e os gráficos apresentaram boa continuidade. Conclusão: O método proposto de compensação matemática baseada em software na mudança de posição do paciente em exames de manometria esofágica perfusional é factível e acurado.pt_BR
dc.description.abstractObjective: To validate a software-based mathematical compensation method for the interference caused by changing the patient's position in perfusional esophageal manometry exams. Methods: The work was carried out in four stages: a) physical and mathematical modeling, b) software implementation, c) ex-vivo tests and d) in vivo tests. In (a), a theoretical mathematical model of the operation of a perfusion equipment was constructed, using mainly the concepts of fluid mechanics. Based on the equations obtained, a software-based compensation method for the interference generated when there is a change in the patient's position was proposed. In (b), the proposed method was effectively implemented in a commercial software to perform high resolution esophageal manometry exams. In (c), the developed software underwent laboratory tests, and the measurements were compared to those predicted theoretically. In (d), exams were carried out on five volunteers to verify the usability of the software in real conditions. Results: No significant differences were found (p=0.3) between the theoretical values predicted in (a) and implemented in (b) and those obtained experimentally in (c). In the in-vivo tests, the analysis of exams in both positions could be carried out seamlessly by the operator, the interferences were eliminated and the graphs presented good continuity. Conclusion: The proposed software-based mathematical compensation method for changing the patient's position in perfusion esophageal manometry examinations is feasible and accurate.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.emailadvisor.customherbella.dcir@epm.brpt_BR
dc.format.extent89 f.pt_BR
dc.identifier.urihttps://repositorio.unifesp.br/handle/11600/70662
dc.languageporpt_BR
dc.publisherUniversidade Federal de São Paulopt_BR
dc.rightsinfo:eu-repo/semantics/openAccesspt_BR
dc.subjectManometriapt_BR
dc.subjectTranstornos da motilidade esofágicapt_BR
dc.subjectExame diagnósticopt_BR
dc.subjectValidação de softwarept_BR
dc.titleAplicabilidade de compensação matemática baseada em software na mudança de posição do paciente em exames de manometria esofágica perfusionalpt_BR
dc.title.alternativeApplicability of mathematical software based compensation for patient’s position change in perfusional esophageal manometryen
dc.typeinfo:eu-repo/semantics/masterThesispt_BR
unifesp.campusEscola Paulista de Medicina (EPM)pt_BR
unifesp.graduateProgramCiência Cirúrgica Interdisciplinarpt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
DissertaçãoME-DanielGualberto2023-PDFA.pdf
Tamanho:
7.65 MB
Formato:
Adobe Portable Document Format
Descrição:
Texto da dissertação
Licença do Pacote
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
5.77 KB
Formato:
Item-specific license agreed upon to submission
Descrição: