Detecção de maculopatia hipotônica subclínica pelo OCT III após cirurgia filtrante

Nenhuma Miniatura disponível
Data
2006-12-01
Autores
Weyll, Mônica
Gilio, Adriana
Barbosa, Aline [UNIFESP]
Nicoli, Aguida Aparecida
Silveira, Regina Cele [UNIFESP]
Orientadores
Tipo
Artigo
Título da Revista
ISSN da Revista
Título de Volume
Resumo
PURPOSE: To detect nondiagnostic hypotony maculopathy by OCT III after filtration surgery. METHODS: After surgery, patients with intraocular pressure less than 9 mmHg were submitted to OCT III examination. RESULTS: Seven (87.50%) patients with previous diagnosis of open angle glaucoma and one (12.50%) of them with acute angle closure glaucoma. Two patients (25.00%) presented hypotony maculopathy on OCT III examination. CONCLUSION: OCT III examination seems to be a good diagnostic method to detect subclinical hypotony maculopathy after filtration surgery.
OBJETIVO: Detectar possíveis sinais de maculopatia hipotônica subclínica por meio da OCT III em pacientes submetidos à cirurgia filtrante. MÉTODOS: Pacientes que realizaram procedimento cirúrgico filtrante com pressão intra-ocular menor que 9 mmHg submeteram-se ao exame OCT III. RESULTADOS: Sete (87,50%) pacientes apresentaram diagnóstico prévio de glaucoma crônico simples e 1 (12,50%) de glaucoma agudo de ângulo fechado. Apenas duas pacientes (25,00%) apresentaram maculopatia hipotônica detectada pela OCT III. CONCLUSÃO: A OCT III parece ser um bom método diagnóstico de maculopatia hipotônica subclínica em pacientes submetidos à cirurgia filtrante convencional.