Navegando por Palavras-chave "Devices"
Agora exibindo 1 - 2 de 2
Resultados por página
Opções de Ordenação
- ItemAcesso aberto (Open Access)Comparação entre diferentes equipamentos utilizados na avaliação do paciente para a cirurgia de catarata(Universidade Federal de São Paulo (UNIFESP), 2017-08-31) Ventura, Bruna Vieira Oliveira Carvalho [UNIFESP]; Mattos, Rubens Belfort [UNIFESP]; Weikert, Mitchell; http://lattes.cnpq.br/4270399167335564; http://lattes.cnpq.br/6038691930130162; Universidade Federal de São Paulo (UNIFESP)Purpose: To compare the measurements obtained by the Cassini, the Atlas 9000 and the Galilei G2 in normal and post-refractive surgery eyes. To evaluate the repeatability of corneal power and astigmatism measurements acquired by the Cassini in normal eyes, comparing it to those of the Atlas 9000 and the Lenstar LS 900. Furthermore, to compare the biometry measurements and intraocular lens (IOL) power calculations obtained by the Galilei G6 and the IOLMaster 500. Methods: Retrospectively, data was collected and compared regarding corneal power, astigmatism and aberrations measured by the Cassini (limited edition), the Atlas 9000 and the Galilei G2 in normal and post-refractive surgery eyes. Prospectively, three consecutive exams were done in normal eyes with the Cassini (version 1), the Atlas 9000 e the Lenstar LS 900. The intraclass correlation coefficient (ICC) and the within-subject standard deviation (Sw) were calculated. Tthe astigmatism was evaluated using vector analysis. In a subsequent study, the following data was compared between the Galilei G6 and the IOLMaster 500: axial length (AL), keratometry (K), anterior chamber depth (ACD) and IOL power calculation to achieve emetropia using a SN60WF Acrysof IOL and the Haigis formula. The 95% limits of agreement (LoA) were calculated. Results: In the retrospective analysis, there was no statistically significant difference between the devices in mean corneal power measured in normal eyes and post-refractive surgery eyes, and in mean astigmatism magnitude in post-refractive surgery eyes (all P > 0.05). In both groups of patients, there was no significant difference in mean coma and spherical aberration amongst the devices (P > 0.05). In the prospective analysis, the Cassini, Atlas 9000 and Lenstar LS 900 attained good repeatability (ICC > 0.9) in corneal power and astigmatism measurements, except for the Atlas 9000 with regards to J45 (ICC = 0.721). The Sw evidenced that the Cassini had a worst repeatability than the Lenstar LS 900 regarding corneal power (P < 0.0001) and than the Lenstar LS 900 (P = 0.0002) and the Atlas 9000 (P = 0.002) regarding astigmatism magnitude. The Galilei G6 and the IOLMaster 500 attained statistically similar mean of AL, K, ACD and IOL power chosen to reach emmetropia (95% LoA: 0.27 mm; 1.08 diopters (D); 0.66 mm, and 1.56 D, respectively). Conclusion: In normal and post-refractive surgery eyes, the Cassini, Atlas 9000 and Galilei G2 obtained similar mean corneal power, astigmatism, coma and spherical aberration. The Cassini presented a good repeatability in corneal power and astigmatism measurements; however, its performance was worse than that of the Lenstar LS 900 for corneal power and of the Lenstar LS 900 and the Atlas 9000 for astigmatism magnitude. The Galilei G6 and the IOLMaster 500 obtained similar mean biometric measurements and mean IOL power chosen to reach emmetropia. However, the wide range of differences amongst the devices suggests they should not be used interchangeably.
- ItemAcesso aberto (Open Access)Malhas para prevenção de lesões por pressão nas regiões de proeminências ósseas do quadril – revisão sistematizada de literatura(Universidade Federal de São Paulo (UNIFESP), 2020-11-17) Severiano, Eneas Jose Figueiredo [UNIFESP]; Ferreira, Lydia Masako [UNIFESP]; Universidade Federal de São PauloIntroduction: The pressure injuries result from the continuous pressure exertec by bony pcoeminences in the tegument pressed against a surface. Apparatus and devices have beem proposed in na attempt do mitigate the pressure in these áreas, mosf of which are highly complex and costly, which makes it difficult to adhere to treatment, especially after hospital discharge. Objective: To perform a literature review and search for anteriority on meshes or clothing to prevent pressure injuires in the regions of bony proeminences of the hip. Method: The search covered from April 1988 to July 2020. It was carried on the databases (Cochrane Library, Lilacs, Scielo, Medline, Web of Science & SSOPUS), having as inclusion criteria clothing aimed at preventing pressure injuries in the region of bone proeminences of the hip; there was no criteria of non-inclusion. The search of anteriority was made in the patent databases: LATIPAT (Espace Patent Search), Google Patent Search, USPTO (United States Patent and Tradmark Office), WiPO (Wordl Intellectual Property Organization), JPO (Japan Property Office, CNIPA (National Intellectual Property Agency – China) and INPI – e-patents (National Intellectual Property Institute. Results: two garments were found in the patent bases. Conclusion: No results were found for searches with the Keywords “prevention”, “injury”, “pressure”, “clothing”, “mesh” and related terms in the scientific literature. Two garments were found in the patent bases.