The validation of the Z-Scan technique for the determination of plasma glucose
dc.contributor.author | Alves, Sarah I. [UNIFESP] | |
dc.contributor.author | Silva, Elaine A. O. [UNIFESP] | |
dc.contributor.author | Costa, Simone S. | |
dc.contributor.author | Sonego, Denise R. N. [UNIFESP] | |
dc.contributor.author | Hallack, Maira L. [UNIFESP] | |
dc.contributor.author | Coppini, Ornela L. [UNIFESP] | |
dc.contributor.author | Rowies, Fernanda [UNIFESP] | |
dc.contributor.author | Azzalis, Ligia A. [UNIFESP] | |
dc.contributor.author | Junqueira, Virginia B. C. [UNIFESP] | |
dc.contributor.author | Pereira, Edimar C. [UNIFESP] | |
dc.contributor.author | Rocha, Katya C. [UNIFESP] | |
dc.contributor.author | Fonseca, Fernando L. A. [UNIFESP] | |
dc.contributor.author | Costa, MFPCM | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.date.accessioned | 2016-01-24T14:31:05Z | |
dc.date.available | 2016-01-24T14:31:05Z | |
dc.date.issued | 2013-01-01 | |
dc.description.abstract | Glucose is the main energy source for the human body. the concentration of blood glucose is regulated by several hormones including both antagonists: insulin and glucagon. the quantification of glucose in the blood is used for diagnosing metabolic disorders of carbohydrates, such as diabetes, idiopathic hypoglycemia and pancreatic diseases. Currently, the methodology used for this determination is the enzymatic colorimetric with spectrophotometric. This study aimed to validate the use of measurements of nonlinear optical properties of plasma glucose via the Z-Scan technique. for this we used samples of calibrator patterns that simulate commercial samples of patients (ELITech(C)). Besides calibrators, serum glucose levels within acceptable reference values (normal control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) and also overestimated (pathological control serum - Brazilian Society of Clinical Pathology and Laboratory Medicine) were used in the methodology proposal. Calibrator dilutions were performed and determined by the Z-Scan technique for the preparation of calibration curve. in conclusion, Z-Scan method can be used to determinate glucose levels in biological samples with enzymatic colorimetric reaction and also to apply the same quality control parameters used in biochemistry clinical. | en |
dc.description.affiliation | Universidade Federal de São Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Diadema, SP, Brazil | |
dc.description.affiliationUnifesp | Universidade Federal de São Paulo, Inst Ciencias Ambientais Quim & Farmaceut, ICAQF, Diadema, SP, Brazil | |
dc.description.source | Web of Science | |
dc.format.extent | 6 | |
dc.identifier | http://dx.doi.org/10.1117/12.2025994 | |
dc.identifier.citation | 8th Iberoamerican Optics Meeting and 11th Latin American Meeting On Optics, Lasers, and Applications. Bellingham: Spie-int Soc Optical Engineering, v. 8785, 6 p., 2013. | |
dc.identifier.doi | 10.1117/12.2025994 | |
dc.identifier.issn | 0277-786X | |
dc.identifier.uri | http://repositorio.unifesp.br/handle/11600/35839 | |
dc.identifier.wos | WOS:000328616100016 | |
dc.language.iso | eng | |
dc.publisher | Spie-int Soc Optical Engineering | |
dc.relation.ispartof | 8th Iberoamerican Optics Meeting and 11th Latin American Meeting On Optics, Lasers, and Applications | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | Z-Scan | en |
dc.subject | Nonlinear Optics | en |
dc.subject | Biomedical Optics | en |
dc.subject | Glucose | en |
dc.subject | Calibration Curve | en |
dc.title | The validation of the Z-Scan technique for the determination of plasma glucose | en |
dc.type | info:eu-repo/semantics/conferenceObject |