Three-dimensional power Doppler placental vascularisation indices in early pregnancy: A pilot study

dc.contributor.authorAraujo Junior, E. [UNIFESP]
dc.contributor.authorNardozza, L. M. M. [UNIFESP]
dc.contributor.authorNowak, P. M. [UNIFESP]
dc.contributor.authorRolo, L. C. [UNIFESP]
dc.contributor.authorGuimaraes Filho, H. A. [UNIFESP]
dc.contributor.authorMoron, A. F. [UNIFESP]
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.date.accessioned2016-01-24T14:16:44Z
dc.date.available2016-01-24T14:16:44Z
dc.date.issued2011-05-01
dc.description.abstractThe objective of our study was to assess 1st trimester placental vascularisation using three-dimensional (3D) power Doppler vascular indices. A cross-sectional study was used involving 41 normal pregnancies from 7 to 10 + 6 weeks. Placental volume was obtained using the 30 degrees virtual organ computer-aided analysis (VOCAL) method. the mean, median, standard deviation (SD), minimum and maximum values were calculated for three vascular indices: the VI, vascularisation index; the FI, flow index and the VFI, vascularisation and flow index. Pearson's correlation coefficient (r) was used to assess the correlation between vascular indices and crown-rump length (CRL). Our results showed mean (+/- SD) values ranged from 8.66 +/- 12.04 to 15.34 +/- 13.89 for the VI, from 63.83 +/- 43.61 to 109.22 +/- 33.87 for the FI and from 9.52 +/- 13.86 to 20.59 +/- 22.97 for the VFI. There was no correlation between CRL and VI (r = 0.073, p = 0.630) nor VFI (r = 0.147 and p = 0.037); there was a weak correlation between CRL and FI (r = 0.332, p = 0.037). It was concluded that the FI was the only 3D power Doppler vascular index that was correlated with CRL between 7 and 10 + 6 weeks' gestation.en
dc.description.affiliationSão Paulo Fed Univ UNIFESP, Dept Obstet, São Paulo, Brazil
dc.description.affiliationUnifespSão Paulo Fed Univ UNIFESP, Dept Obstet, São Paulo, Brazil
dc.description.sourceWeb of Science
dc.format.extent283-285
dc.identifierhttp://dx.doi.org/10.3109/01443615.2011.558647
dc.identifier.citationJournal of Obstetrics and Gynaecology. New York: Informa Healthcare, v. 31, n. 4, p. 283-285, 2011.
dc.identifier.doi10.3109/01443615.2011.558647
dc.identifier.issn0144-3615
dc.identifier.urihttp://repositorio.unifesp.br/handle/11600/33693
dc.identifier.wosWOS:000290147300002
dc.language.isoeng
dc.publisherInforma Healthcare
dc.relation.ispartofJournal of Obstetrics and Gynaecology
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rights.licensehttp://informahealthcare.com/userimages/ContentEditor/1255620309227/Copyright_And_Permissions.pdf
dc.subjectCrown-rump lengthen
dc.subjectplacentaen
dc.subjectpower Doppleren
dc.subjectthree-dimensional imagingen
dc.titleThree-dimensional power Doppler placental vascularisation indices in early pregnancy: A pilot studyen
dc.typeinfo:eu-repo/semantics/article