Internal carotid artery aneurysm mimicking normal-tension glaucoma

dc.citation.issue2
dc.citation.volumev. 81
dc.contributor.authorPincelli Netto, Mario [UNIFESP]
dc.contributor.authorFerrari, Pedro Vanalle [UNIFESP]
dc.contributor.authorHerrerias, Bruno Torres [UNIFESP]
dc.contributor.authorHirai, Flavio Eduardo [UNIFESP]
dc.contributor.authorGracitelli, Carolina Pelegrini Barbosa [UNIFESP]
dc.coverageSao Paulo
dc.date.accessioned2020-07-20T16:31:17Z
dc.date.available2020-07-20T16:31:17Z
dc.date.issued2018
dc.description.abstractDifferentiating glaucomatous from nonglaucomatous optic disc cupping remains challenging. We present a case of a 48-year-old woman with an internal carotid aneurysm of approximately 3.5 mm x 6.5 mm that mimicked normal-tension glaucoma. The patient had a 2-year history of low vision acuity in her left eye and frontal oppressive headache. Owing to the carotid aneurysm, she developed an asymmetric vertical cup-to-disc ratio above 0.2, and marked inferotemporal neuronal rim loss and pallor of the residual rim were noted in the left disc. She also developed a visual field defect with an arcuate scotoma in the left eye. The patient was referred to a neurosurgeon and underwent endovascular aneurysm occlusion. This case highlights the diagnostic importance of recognizing that many neurological defects remain underdiagnosed.en
dc.description.abstractA diferenciação de escavações glaucomatosas e não glaucomatosas ainda permanece um desafio ainda nos dias de hoje. Nos descrevemos um caso de aneurisma de carótida interna medindo 3.5mm x 6.5mm que simulava um glaucoma de pressão normal. O caso é sobre uma paciente feminino de 48 anos com história de 2 anos de baixa acuidade visual no olho esquerdo e cefaléia frontal. Devido ao aneurisma de carótida a paciente desenvolveu uma assimetria de escavação vertical maior que 0.2 no olho esquerdo em relação ao direito com defeito localizado da camada de fibras nervosas temporal inferior. Ela também apresentava um defeito arqueado temporal superior a esquerda, cruzando a linha média vertical consistente. Após o diagnostico confirmado pela ressonância magnética funcional, a paciente foi enviada para o neurocirurgião para realização de uma oclusão endovascular do aneurisma. Esse caso nos alerta da importância de se lembrar que não apenas o glaucoma gera escavações suspeitas no disco óptico e que ainda muitos defeitos por causas neurológicas são subdiagnosticados.pt
dc.description.affiliationUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, SP, Brazil
dc.description.affiliationVer Mais Oftalmol, Glaucoma Unit, Sao Paulo, SP, Brazil
dc.description.provenanceMade available in DSpace on 2020-07-20T16:31:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2018. Added 1 bitstream(s) on 2020-07-20T17:36:27Z : No. of bitstreams: 1 S0004-27492018000200148.pdf: 464430 bytes, checksum: 69f0f82b5c458ec52bdd15254a7743b9 (MD5)en
dc.description.sourceWeb of Science
dc.format.extent148-152
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492018000200148&lng=en&nrm=iso&tlng=en
dc.identifier.citationArquivos Brasileiros De Oftalmologia. Sao Paulo, v. 81, n. 2, p. 148-152, 2018.
dc.identifier.doi10.5935/0004-2749.20180032
dc.identifier.fileS0004-27492018000200148.pdf
dc.identifier.issn0004-2749
dc.identifier.scieloS0004-27492018000200148
dc.identifier.urihttps://repositorio.unifesp.br/handle/11600/55842
dc.identifier.wosWOS:000433360900013
dc.language.isoeng
dc.publisherConsel Brasil Oftalmologia
dc.relation.ispartofArquivos Brasileiros De Oftalmologia
dc.rightsAcesso aberto
dc.subjectGlaucoma/diagnosisen
dc.subjectCarotid artery, internalen
dc.subjectOphthalmic artery/pathologyen
dc.subjectAneurysm/diagnosisen
dc.subjectVisual fielden
dc.subjectDifferential diagnosisen
dc.subjectGlaucoma/diagnósticopt
dc.subjectCarótida internapt
dc.subjectArtéria oftálmica/patologiapt
dc.subjectAneurisma/diagnósticopt
dc.subjectCampo visualpt
dc.subjectDiagnóstico diferencialpt
dc.titleInternal carotid artery aneurysm mimicking normal-tension glaucomaen
dc.title.alternativeAneurisma de carótida interna simulando glaucoma de pressão normalpt
dc.typeArtigo
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0004-27492018000200148.pdf
Tamanho:
453.54 KB
Formato:
Adobe Portable Document Format
Descrição: