Utilidade clínica da aquisição tecidual de lesões císticas pancreáicas por agulha guiada por ultrassom endoscópico para análise histológica

dc.contributor.advisorArdengh, José Celso
dc.contributor.advisorLatteshttp://lattes.cnpq.br/7156173153438406
dc.contributor.authorCastro, Juliana Silveira Lima de [UNIFESP]
dc.contributor.authorLatteshttp://lattes.cnpq.br/8984101229775874
dc.coverage.spatialSão Paulo
dc.date.accessioned2024-05-13T17:41:54Z
dc.date.available2024-05-13T17:41:54Z
dc.date.issued2024-04-18
dc.description.abstractObjetivos: determinar acurácia diagnóstica da biópsia guiada por ultrassom endoscópico com a agulha dedicada a aquisição tecidual para diferenciar entre neoplasia mucinosa e não-mucinosa e identificar as lesões císticas pancreáticas malignas bem como seus eventos adversos (sangramento, pancreatite aguda, infecção e perfuração) em pacientes com lesões císticas pancreáticas sem diagnóstico classificatório por exames de imagem. Métodos: Neste estudo observacional, retrospectivo, em centro único, todos os pacientes com lesões císticas pancreáticas que foram submetidos a biópsia por agulha guiada por ultrassom endoscópico devido a dúvidas diagnóstica em exames de imagem ou que durante o seguimento apresentaram pancreatite aguda, elevação do CA 19.9, tiveram aparecimento de diabetes ou apresentaram parentes com câncer de pâncreas, foram recrutados consecutivamente no período de junho de 2017 a dezembro de 2021. Resultados: Cento e quarenta e cinco pacientes foram submetidos a biópsia por agulha fina guiado por ultrassom endoscópico, sendo 83 mulheres (57.2%), média de idade de 62.2 anos (21-91 anos). O tamanho médio foi de 2.3 cm (0.6 a 10 cm) e 81 (77.9%) eram menores que 3,0 cm. O diagnóstico final foi obtido pela biópsia por agulha fina guiada por ultrassom endoscópico (81), cirurgia (58) e seguimento (6). A prevalência das lesões neoplásicas na amostra foi 25 (17%). A sensibilidade, especificidade, valor preditivo positivo, negativo e acurácia para o diferencial entre neoplasia mucinosa e não mucinosa e uma lesão cística pancreática maligna foram de 92.6%, 98.4%, 98.7%, 91.3% e 95.2% (kappa=0.9) e 92%, 99.2%, 95.8%, 98.3% e 97.9% (Kappa=0.93), respectivamente. A taxa de eventos adversos foi 2,7% sem mortes nessa coorte. Conclusão: A biópsia por agulha fina guiada por ultrassom endoscópico tem elevada acurácia e sucesso técnico com baixa taxa de eventos adversos. Esses resultados mostram que este método é preciso além de ser seguro, para o diagnóstico de uma lesão cística pancreática duvidosa. Mais estudos multicêntricos, randomizados, controlados e prospectivos serão necessários para confirmar esses resultados iniciais. pt_BR
dc.description.abstractObjectives: This study aimed to determine the accuracy of endosonography-guided tissue acquisition with ProCore 20G for differentiating between mucinous neoplasia and non-mutinous neoplasia and identifying malignant pancreatic cystic lesions, as well as its adverse events (bleeding, acute pancreatitis, infection and perforation) in patients with pancreatic cystic lesions without a classificatory diagnosis by imaging exams. Methods: In this observational, retrospective, single-center study, all patients with pancreatic cystic lesions who underwent endosonography-guided tissue acquisition due to diagnostic doubts in imaging studies were consecutively recruited from June 2017 to December 2021. Results: In this study, 145 patients underwent fine needle biopsy guided by endoscopic ultrasound, 83 women (57.2%), mean age 62.2 years (21-91 years). The mean size was 2.3 cm (0.6 to 10 cm) and 81 (77.9%) were smaller than 3.0 cm. The final diagnosis was obtained by fine needle biopsy guided by endoscopic ultrasound (81), surgery (58) and follow-up (6). The prevalence of neoplastic lesions in the sample was 25 (17%). The sensitivity, specificity, positive and negative predictive value and accuracy for the differential between mucinous and non-mucinous cystic neoplasms and a malignant pancreatic cystic lesions were 92.6%, 98.4%, 98.7%, 91.3% and 95.2% (kappa=0.9) and 92%, 99.2%, 95.8%, 98.3% and 97.9% (Kappa=0.93), respectively. The adverse events rate was 2.7% with no deaths in this cohort. Conclusion: Fine needle biopsy guided by endoscopic ultrasound with the 20 Gauge ProCore has high accuracy and technical success with a low rate of adverse events. These results show that fine needle biopsy guided by endoscopic ultrasound is accurate as well as safe for the diagnosis of dubious pancreatic cystic lesions. More multicenter, randomized, controlled and prospective studies will be needed to confirm these initial results.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.emailadvisor.customjcelso@uol.com.br
dc.format.extent49 f.
dc.identifier.citationCASTRO, Juliana Silveira Lima de. Utilidade clínica da aquisição tecidual de lesões císticas pancreáicas por agulha guiada por ultrassom endoscópico para análise histológica. 2024. 49 f. Dissertação (Mestrado em Radiologia Clínica) - Escola Paulista de Medicina, Universidade Federal de São Paulo (UNIFESP). São Paulo, 2024.pt_BR
dc.identifier.urihttps://hdl.handle.net/11600/71095
dc.languagepor
dc.publisherUniversidade Federal de São Paulo
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAspiraçãopt_BR
dc.subjectIntervenção ecoendoscópicapt_BR
dc.subjectPâncreaspt_BR
dc.subjectDiagnóstico tecidualpt_BR
dc.subjectBiópsia por agulha finapt_BR
dc.titleUtilidade clínica da aquisição tecidual de lesões císticas pancreáicas por agulha guiada por ultrassom endoscópico para análise histológicapt_BR
dc.title.alternativeClinical usefulness of tissue acquisition of pancreatic cystic lesions using an endoscopic ultrasound-guided needle for histological analysisen
dc.typeinfo:eu-repo/semantics/masterThesis
unifesp.campusEscola Paulista de Medicina (EPM)
unifesp.graduateProgramMedicina (Radiologia Clínica)
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Dissertação_Juliana_Castro.pdf
Tamanho:
803.6 KB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
5.55 KB
Formato:
Item-specific license agreed upon to submission
Descrição: