Desenvolvimento de estimulador vagal auricular retroalimentado controlado por sinal respiratório

dc.contributor.advisorCasali, Karina Rabello
dc.contributor.advisor-coUchiyama, Tatiana de Sousa da Cunha
dc.contributor.advisor-coAmorim, Henrique Alves de
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/6737487161341934pt_BR
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/2867784853735791pt_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/2188710413184266pt_BR
dc.contributor.authorFaria, Gabriella Maria de [UNIFESP]
dc.contributor.authorLatteshttp://lattes.cnpq.br/3519076718437012pt_BR
dc.coverage.spatialUNIFESPpt_BR
dc.date.accessioned2023-11-27T11:09:23Z
dc.date.available2023-11-27T11:09:23Z
dc.date.issued2023-08-22
dc.description.abstractO nervo vago é fundamental no Sistema Nervoso Autonômico, regulando a homeostase corporal. A estimulação transcutânea auricular do nervo vago (taVNS) é uma modalidade terapêutica que apresenta resultados potenciais em distúrbios crônicos sem a necessidade de procedimentos cirúrgicos para implantação de eletrodos. Estudos recentes apontam que a estimulação vagal sincronizada com a expiração otimiza as respostas terapêuticas da taVNS. Isso envolve o biofeedback do Núcleo Trato Solitário, influenciando o ritmo cardíaco e reflexos pulmonares. Neste contexto, a dissertação apresenta o desenvolvimento de um dispositivo de estimulação vagal transcutânea com retroalimentação do sinal expiratório. Metodologias de instrumentação, sistemas embarcados, aquisição e processamento de sinais são empregados para a criação do protótipo. Sensores vestíveis e monitoramento em tempo real dos dados em plataformas de visualização fazem parte do dispositivo desenvolvido, que embarca algoritmos para processamento sequencial em microcontroladores. O dispositivo foi projetado por meio de softwares de design eletrônico e modelagem tridimensional, e fabricado com placas PCB para os circuitos e fabricação aditiva para o encapsulamento. Os sinais coletados durante a terapia, incluindo os momentos em que a fase de expiração é identificada, são comparados com a detecção de picos do software, indicando boa acurácia do código implementado. Com a capacidade de avaliar os efeitos terapêuticos em tempo real, a abordagem proposta permite o emprego do biofeedback no contexto da estimulação transcutânea, com oportunidade de personalização do tratamento para cada paciente. Os progressos alcançados durante o mestrado e apresentados nos artigos podem ser associados à evolução tecnológica da pesquisa em curso, como o nível de maturidade tecnológica, conhecido como TRL (Technology Readiness Level). Neste contexto, o protótipo atual está caracterizado como TRL4, com a validação do estimulador em ambiente laboratorial. A temática abordada no mestrado é de natureza multidisciplinar, evidenciando o potencial da engenharia biomédica no desenvolvimento de soluções para melhorar a eficácia de tecnologias de intervenção e tratamento terapêutico, como é o caso da terapia inovadora da taVNS retroalimentada por sinais fisiológicos.pt_BR
dc.description.abstractThe vagus nerve is essential within the Autonomic Nervous System, regulating bodily homeostasis. Transcutaneous auricular vagus nerve stimulation (taVNS) is a therapeutic modality with potential outcomes in chronic disorders, obviating the need for surgical electrode implantation. Recent studies indicate that synchronized vagal stimulation with exhalation optimizes taVNS therapeutic responses. This involves the feedback loop of the Solitary Tract Nucleus, influencing heart rate and pulmonary reflexes through respiratory sinus arrhythmia. In this context, the dissertation presents the development of a transcutaneous vagal stimulation device with expiratory signal feedback. Methodologies encompassing instrumentation, embedded systems, signal acquisition, and processing contribute to the prototype's creation. Wearable sensors and real-time monitoring of data through visualization platforms are integral to the developed device, embedding algorithms for sequential processing in microcontroller. The device was designed using electronic design and three-dimensional modeling software, and fabricated using PCB boards for circuitry and additive manufacturing for encapsulation. Signals recorded during therapy, including instances of exhalation phase identification, are compared with software peak detection, demonstrating accurate code implementation. With the capacity to assess therapeutic effects in real-time, the proposed approach enables the integration of biofeedback into transcutaneous stimulation, allowing for personalized treatment for each patient. The advancements achieved during the master's program, presented in the articles, can be linked to the ongoing technological evolution of the research, measured through the Technology Readiness Level (TRL). Within this framework, the current prototype is classified as TRL4, validated within a laboratory setting. The master's thematic focus is interdisciplinary, showcasing the potential of biomedical engineering in developing solutions to enhance the effectiveness of intervention technologies and therapeutic treatments. A prime example is the innovative therapy of feedback-enabled taVNS based on physiological signals.pt_BR
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)pt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt_BR
dc.description.sponsorshipID434446/2018-1pt_BR
dc.emailadvisor.customrabello.casali@unifesp.brpt_BR
dc.format.extent59 f.pt_BR
dc.identifier.urihttps://repositorio.unifesp.br/handle/11600/69542
dc.languageporpt_BR
dc.publisherUniversidade Federal de São Paulopt_BR
dc.rightsinfo:eu-repo/semantics/restrictedAccesspt_BR
dc.subjectNeuromodulationpt_BR
dc.subjecttaVNSpt_BR
dc.subjectclosed-looppt_BR
dc.subjectNode-REDpt_BR
dc.subjectSimpatovagal Modulationpt_BR
dc.subjectHeart Rate Variabilitypt_BR
dc.subjectAutonomic Nervous Systempt_BR
dc.subjectVagus nerve stimulationpt_BR
dc.titleDesenvolvimento de estimulador vagal auricular retroalimentado controlado por sinal respiratóriopt_BR
dc.typeinfo:eu-repo/semantics/masterThesispt_BR
unifesp.campusInstituto de Ciência e Tecnologia (ICT)pt_BR
unifesp.graduateProgramEngenharia Biomédicapt_BR
unifesp.knowledgeAreaINSTRUMENTAÇÃO BIOMÉDICApt_BR
unifesp.researchAreaInstrumentos Biomédicospt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Dissertação_Gabriella_Repositorio.pdf
Tamanho:
4.95 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
5.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: