Nível de pressão sonora em Unidade de Terapia Intensiva Neonatal
Data
2011-12-01
Tipo
Artigo
Título da Revista
ISSN da Revista
Título de Volume
Resumo
The objectives of the study were to assess sound pressure level (SPL) in two rooms of a Neonatal Intensive Care Unit (NICU) and to identify their sources. This quantitative-descriptive study was conducted in two rooms of a NICU of a University Hospital in São Paulo, Brazil. Three dosimeters were used to register SPL (total of 261 hours). A 48-hour register of noise sources was obtained. The results showed high SPL in both rooms. The greatest mean Leq were 71.0 dBA (room A) and 68.0 dBA (room B). Main noise sources in both units were: NICU hallway noise, traffic and conversation among professionals. The results indicate that SPLs in NICU rooms are higher than the levels recommended by regulatory agencies. A guideline was developed and an educational program was implemented as a means to reduce sound pressure levels.
Este estudio objetivó verificar el nivel de presión sonora (NPS) de dos salas de Unidad de Terapia Intensiva Neonatal (UTIN) e identificar sus fuentes. Estudio cuantitativo, descriptivo, llevado a cabo en dos salas de UTIN de hospital universitario de San Pablo-SP-Brasil. Se realizaron registros de NPS con tres dosímetros, totalizando 261 horas de medición. Se obtuvieron 48 horas de registros de las fuentes que producen ruidos. Los resultados indican elevados niveles de presión sonora en ambos ambientes. Los mayores Leq medios fueron 71,0 dBA en sala A y 68,0 dBA en sala B. Las principales fuentes de ruido encontradas fueron: ruidos en el corredor, tránsito y conversación entre profesionales. Los resultados revelan que los NPS de salas de UTIN distan de ser los recomendados por los órganos reguladores. Se desarrolló protocolo y se implementó programa educativo, apuntando a la reducción de la presión sonora.
Os objetivos deste estudo foram verificar o nível de pressão sonora (NPS) de duas salas de Unidade de Terapia Intensiva Neonatal (UTIN) e identificar as suas fontes. É uma pesquisa quantitativa, descritiva, conduzida em duas salas de UTIN de hospital universitário de São Paulo - SP, Brasil. Registros de NPS foram realizados por três dosímetros, totalizando 261 horas de mensuração. Obteve-se 48 horas de registros das fontes que produzem ruídos. Os resultados indicam elevados níveis de pressão sonora nos dois ambientes. Os maiores níveis de Leq foram 71,0 dBA na sala A e 68,0 dBA na sala B. As principais fontes de ruído encontradas nas duas unidades foram ruído no corredor, trânsito e conversa entre os profissionais. Os resultados revelam que os NPS das salas da UTIN estão distantes dos recomendados pelos órgãos regulamentadores. Foi desenvolvido um protocolo e implementado um programa educativo, visando à redução dos níveis de pressão sonora.
Este estudio objetivó verificar el nivel de presión sonora (NPS) de dos salas de Unidad de Terapia Intensiva Neonatal (UTIN) e identificar sus fuentes. Estudio cuantitativo, descriptivo, llevado a cabo en dos salas de UTIN de hospital universitario de San Pablo-SP-Brasil. Se realizaron registros de NPS con tres dosímetros, totalizando 261 horas de medición. Se obtuvieron 48 horas de registros de las fuentes que producen ruidos. Los resultados indican elevados niveles de presión sonora en ambos ambientes. Los mayores Leq medios fueron 71,0 dBA en sala A y 68,0 dBA en sala B. Las principales fuentes de ruido encontradas fueron: ruidos en el corredor, tránsito y conversación entre profesionales. Los resultados revelan que los NPS de salas de UTIN distan de ser los recomendados por los órganos reguladores. Se desarrolló protocolo y se implementó programa educativo, apuntando a la reducción de la presión sonora.
Os objetivos deste estudo foram verificar o nível de pressão sonora (NPS) de duas salas de Unidade de Terapia Intensiva Neonatal (UTIN) e identificar as suas fontes. É uma pesquisa quantitativa, descritiva, conduzida em duas salas de UTIN de hospital universitário de São Paulo - SP, Brasil. Registros de NPS foram realizados por três dosímetros, totalizando 261 horas de mensuração. Obteve-se 48 horas de registros das fontes que produzem ruídos. Os resultados indicam elevados níveis de pressão sonora nos dois ambientes. Os maiores níveis de Leq foram 71,0 dBA na sala A e 68,0 dBA na sala B. As principais fontes de ruído encontradas nas duas unidades foram ruído no corredor, trânsito e conversa entre os profissionais. Os resultados revelam que os NPS das salas da UTIN estão distantes dos recomendados pelos órgãos regulamentadores. Foi desenvolvido um protocolo e implementado um programa educativo, visando à redução dos níveis de pressão sonora.