Does the Capsule Interfere with Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Cryptococcus neoformans and Cryptococcus gattii?

dc.citation.issue2
dc.citation.volume54
dc.contributor.authorThomaz, Danilo Y.
dc.contributor.authorGrenfell, Rafaella C. [UNIFESP]
dc.contributor.authorVidal, Monica S. M.
dc.contributor.authorGiudice, Mauro C.
dc.contributor.authorDel Negro, Gilda M. B.
dc.contributor.authorJuliano, Luiz [UNIFESP]
dc.contributor.authorBenard, Gil
dc.contributor.authorde Almeida Junior, Joao N.
dc.coverageWashington
dc.date.accessioned2020-11-03T14:40:36Z
dc.date.available2020-11-03T14:40:36Z
dc.date.issued2016
dc.description.abstractWe described the impact of the capsule size for Cryptococcus neoformans and Cryptococcus gattii identification at the species level by Bruker matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). After experimental capsule size modulation, we observed that reducing the capsule size resulted in improved identification by Bruker MALDI-TOF MS across all of the reference strains analyzed.en
dc.description.affiliationUniv Sao Paulo, Hosp Clin FMUSP, Med Mycol Lab, LIM 53, Sao Paulo, Brazil
dc.description.affiliationUniv Sao Paulo, Inst Trop Med Sao Paulo, LIM 53, Sao Paulo, Brazil
dc.description.affiliationUniv Fed Sao Paulo, Escola Paulista Med, Dept Biophys, Sao Paulo, Brazil
dc.description.affiliationUniv Sao Paulo, Fac Med, Hosp Clin, Cent Lab Div, LIM 03, Sao Paulo, Brazil
dc.description.affiliationUnifespUniv Fed Sao Paulo, Escola Paulista Med, Dept Biophys, Sao Paulo, Brazil
dc.description.provenanceMade available in DSpace on 2020-11-03T14:40:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2016en
dc.description.sourceWeb of Science
dc.format.extent474-477
dc.identifierhttps://doi.org/10.1128/JCM.02635-15
dc.identifier.citationJournal Of Clinical Microbiology. Washington, v. 54, n. 2, p. 474-477, 2016.
dc.identifier.doi10.1128/JCM.02635-15
dc.identifier.issn0095-1137
dc.identifier.urihttps://repositorio.unifesp.br/handle/11600/58641
dc.identifier.wosWOS:000369155100038
dc.language.isoeng
dc.publisherAmer Soc Microbiology
dc.relation.ispartofJournal Of Clinical Microbiology
dc.rightsAcesso aberto
dc.titleDoes the Capsule Interfere with Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Cryptococcus neoformans and Cryptococcus gattii?en
dc.typeArtigo
Arquivos
Coleções