Navegando por Palavras-chave "Raios-X"
Agora exibindo 1 - 2 de 2
Resultados por página
Opções de Ordenação
- ItemSomente MetadadadosDesenvolvimento de índices radiográficos para auxílio ao diagnóstico das lesões perilunares(Universidade Federal de São Paulo (UNIFESP), 2020-03-26) Pinto, Fernando Nogueira Zambone [UNIFESP]; Fernandes, Carlos Henrique [UNIFESP]; Universidade Federal de São PauloObjective: The objective of this study was to develop radiographic indexes that help the diagnostic confirmation of perilunate injuries. Methods: A descriptive, crosssectional, retrospective study was carried out with the objective of finding radiographic indexes that facilitate the diagnosis of perilunate injuries. Eighty wrist radiographs were evaluated, divided into 20 radiographs without changes and 20 radiographs with the following diagnosis: scapholunate ligament injury, transcaphoid fracture dislocation, lunate dislocation. All diagnoses were confirmed by the finding of an anatomical injury during the surgical procedure that treated the respective injuries. In the PA incidence radiographs of the wrist, we determined bone points that originated lines to evaluate the anatomical relationship between the carpal bones. The ulnar translation index (UTI) and the modified carpal height index (MCHI) were measured. On lateral wrist radiographs, bone points were selected that originated lines to evaluate the anatomical relationship between the carpal bones. The radiolunate index (RLI) was calculated. The Kruskal-Wallis test and graphical analysis using box plot were used in the statistical analysis. The result of each comparison presents a p value, being defined as a significance value of 0.05 (5%). Results: The UTI, on the radiographs of the wrists considered without changes, ranged from 0.534 ± 0.058, on the radiographs diagnosed with lesion of the scapholunate ligament, ranged from 0.560 ± 0.075, on the radiographs with diagnosis of transescapho-lunate fracture dislocation, it was found a range from 0.557 ± 0.138 and on the radiographs with a diagnosis of lunate dislocation it ranged from 0.628 ± 0.059. The p-value found for the UTI study was 0.062. The MCHI on the radiographs of the wrists without changes ranged from 2.538 ± 0.152, on the radiographs diagnosed with scapholunate ligament injury ranged from 2.534 ± 0.146, on the radiographs with diagnosis of transescapho-lunate fracture dislocation, ranged from 2.524 ± 0.155, on radiographs with a diagnosis of lunate dislocation ranged from 2.52 ± 0.13. The p-value for MCHI was 0.973. The RLI on the radiographs of the wrists without changes ranged from 1,136 ± 0.172. In the radiographs with diagnosis of scapholunate ligament injury, the index ranged from 1.907 ± 0.428, in the radiographs with diagnosis of transescapho-lunate fracture dislocation, it varied from 0.743 ± 0.099 and in the radiographs with diagnosis of lunate dislocation it ranged from xiv 0.47 ± 0.086 . The p-value for RLI was less than 0.001. Conclusion: The application of the UTI demonstrated that there is a statistical tendency for ulnar translation in the perilunate injuries. Its clinical applicability to aid in the diagnosis of perilunate injury rely on complementary studies. The MCHI has demonstrated that there is no change in carpal height in perilunate injuries. It cannot be clinically applied to aid in the diagnosis of perilunate injuries. The application of the RLI demonstrated that there is a change in the position of the lunate in relation to the articular surface of the radius in perilunate injuries. Thus, it can be applied clinically to aid in the diagnosis of perilunate injuries.
- ItemAcesso aberto (Open Access)Detectores Semicondutores: Histórico e Aplicações(Universidade Federal de São Paulo, 2022-02-11) Coimbra, João Vitor Pereira [UNIFESP]; Barbosa, Renata de Faria [UNIFESP]; http://lattes.cnpq.br/3663691702527038; Universidade Federal de São Paulo (UNIFESP)Este trabalho tem como finalidade apresentar uma revisão da literatura a respeito dos detectores semicondutores, enfatizando o seu desenvolvimento ao longo do tempo e suas aplicações. Para realizar essa compilação de informações sobre esse tipo de detector foi empregada a metodologia de referência bibliográfica. Os dados científicos foram selecionados e coletados utilizando bases de dados nacionais e internacionais, disponíveis de forma online, Science Direct, Scielo (Scientific Eletronic Library Online), Portal da CAPES, Springer LINK, Google Acadêmico/Scholar. O critério de seleção do material científico compreende artigos, teses e textos dos periódicos, livros com conceitos básicos e consolidados claros com palavras chave como: semicondutores, detectores, Raios X, histórico e aplicação utilizando detectores semicondutores. O estudo apresenta a evolução dos detectores semicondutores, explicando como são formados a partir da junção np, os chamados diodos, apresentando o que são os fotodiodos e a importância de sua aplicação na indústria, na medicina e em técnicas que utilizam radiação, já que os detectores semicondutores têm baixo custo e eletrônica simples, em contraste com os detectores à gás. Outra vantagem, deste dispositivo, é a rapidez no tempo de resposta e a eficiência na detecção de ondas de baixa energia, por exemplo, os raios X. Seu desempenho é aplicado para detectar a radiação X característica dos átomos excitados por uma radiação eletromagnética, na técnica de Fluorescência de Raios X, permitindo a identificação da composição e concentração de elementos presentes em uma amostra de natureza diversas (ambiental, alimentícia, industrial, geológica, etc.).