Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/34991
Title: Endotracheal tube cuff pressure assessment maneuver induces drop of expired tidal volume in the postoperative of coronary artery bypass grafting
Authors: Bolzan, Douglas W. [UNIFESP]
Guizilini, Solange [UNIFESP]
Faresin, Sonia M. [UNIFESP]
Carvalho, Antonio C. C. [UNIFESP]
De Paola, Angelo Amato Vincenzo [UNIFESP]
Gomes, Walter J. [UNIFESP]
Universidade Federal de São Paulo (UNIFESP)
Keywords: Coronary artery bypass grafting
Endotracheal tube cuff pressure
Air leakage
Expired tidal volume
Mechanical ventilation
Issue Date: 10-Jun-2012
Publisher: Biomed Central Ltd
Citation: Journal of Cardiothoracic Surgery. London: Biomed Central Ltd, v. 7, 5 p., 2012.
Abstract: Background: Previous investigations reported that the cuff pressure (CP) can decrease secondary to the CP evaluation itself. However is not established in literature if this loss of CP is able to generate alterations on expired tidal volume (ETV). Therefore, the aim of this study was to evaluate the potential consequences of the endotracheal CP assessment maneuver on CP levels and ETV in the early postoperative of coronary artery bypass grafting (CABG).Methods: A total of 488 patients were analyzed. After the operation, the lungs were ventilated in pressure-assist control mode and the same ventilatory settings were adjusted for all patients. After intensive care unit arrival, the cuff was fully deflated and then progressively inflated by air injection, to promote a minimal volume to occlude the trachea. To assist the cuff inflation and the air leakage identification, the graphical monitoring of the volume-time curve was adopted. After 20 minutes a first cuff pressure evaluation was performed (P1) and a second measurement (P2) was taken after 20 minutes with an analog manometer. ETV was obtained always pre and post P1 measurement.Results: the CP assessment maneuver promoted a significant drop of P2 in relation to P1 when the manometer was attached to the pilot balloon (p < 0.0001). When compared the moments, pre-P1 versus post-P1, a significant drop of the ETV was also observed (p < 0.0001).Conclusion: the CP assessment maneuver promoted a significant decrease in CP values and occurrence of air leakage with reduction of ETV in the early postoperative of CABG.
URI: http://repositorio.unifesp.br/handle/11600/34991
ISSN: 1749-8090
Other Identifiers: http://dx.doi.org/10.1186/1749-8090-7-53
Appears in Collections:Em verificação - Geral

Files in This Item:
File Description SizeFormat 
WOS000306808000001.pdf316.61 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.