Qualidade visual após retratamento de LASIK personalizado versus convencional
dc.contributor.author | Urbano, Andréia Peltier | |
dc.contributor.author | Nosé, Walton [UNIFESP] | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.contributor.institution | Universidade Metropolitana de Santos Departamento de Oftalmologia | |
dc.date.accessioned | 2015-06-14T13:38:55Z | |
dc.date.available | 2015-06-14T13:38:55Z | |
dc.date.issued | 2008-12-01 | |
dc.description.abstract | PURPOSE: To evaluate visual quality after wavefront-guided LASIK versus standard LASIK in retreatment of primary LASIK for myopia and myopic astigmatism. METHODS: A prospective study was performed with paired eye control of 74 eyes with LASIK retreatment. Each patient underwent retreatment using custom ablation (Zyoptix, Bausch & Lomb) in 1 eye and standard ablation LASIK (PlanoScan, Bausch & Lomb) in the contralateral eye. A complete ophthalmologic examination was performed, including evaluation of glare test and contrast sensitivity test, with a follow-up of 6 months. RESULTS: Zyoptix eyes showed better results of glare test and contrast sensitivity test than the contralateral eyes. CONCLUSIONS: Wavefront-guided LASIK produces better visual quality than standard LASIK in the retreatment of refractive errors after primary LASIK. | en |
dc.description.abstract | OBJETIVO: Avaliar a qualidade visual após retratamento personalizado e retratamento convencional em olhos submetidos a LASIK primário convencional. MÉTODOS: Foi realizado estudo prospectivo de 74 olhos submetidos ao retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido ao retratamento de LASIK com ablação personalizada (Zyoptix, Bausch & Lomb) em um olho e ablação convencional (Planoscan, Bausch & Lomb) no olho contralateral. Foram comparados os resultados do teste de ofuscamento e da sensibilidade ao contraste durante o acompanhamento de seis meses. RESULTADOS: Os olhos do grupo Zyoptix apresentaram melhores resultados no teste de ofuscamento e na sensibilidade ao contraste do que o olho contralateral, quando se compararam os resultados. CONCLUSÕES: O retratamento personalizado resultou em melhor qualidade visual pós-operatória do que o retratamento convencional de LASIK primário convencional. | pt |
dc.description.affiliation | UNIFESP Departamento de Oftalmologia | |
dc.description.affiliation | Universidade Metropolitana de Santos Departamento de Oftalmologia | |
dc.description.affiliationUnifesp | UNIFESP, Depto. de Oftalmologia | |
dc.description.source | SciELO | |
dc.format.extent | 841-846 | |
dc.identifier | http://dx.doi.org/10.1590/S0004-27492008000600015 | |
dc.identifier.citation | Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 71, n. 6, p. 841-846, 2008. | |
dc.identifier.doi | 10.1590/S0004-27492008000600015 | |
dc.identifier.file | S0004-27492008000600015.pdf | |
dc.identifier.issn | 0004-2749 | |
dc.identifier.scielo | S0004-27492008000600015 | |
dc.identifier.uri | http://repositorio.unifesp.br/handle/11600/4735 | |
dc.identifier.wos | WOS:000208670500017 | |
dc.language.iso | por | |
dc.publisher | Conselho Brasileiro de Oftalmologia | |
dc.relation.ispartof | Arquivos Brasileiros de Oftalmologia | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Quality | en |
dc.subject | Vision | en |
dc.subject | Keratomileusis, laser in situ | en |
dc.subject | Retreatment | en |
dc.subject | Lasers | en |
dc.subject | Myopia | en |
dc.subject | Refractive errors | en |
dc.subject | Qualidade | pt |
dc.subject | Visão | pt |
dc.subject | Ceratomileuse assistida por excimer laser in situ | pt |
dc.subject | Retratamento | pt |
dc.subject | Lasers | pt |
dc.subject | Miopia | pt |
dc.subject | Erros de refração | pt |
dc.title | Qualidade visual após retratamento de LASIK personalizado versus convencional | pt |
dc.title.alternative | Visual quality after custom versus standard LASIK retreatment | en |
dc.type | info:eu-repo/semantics/article |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S0004-27492008000600015.pdf
- Tamanho:
- 532.17 KB
- Formato:
- Adobe Portable Document Format
- Descrição: