Second-generation central venous catheter in the prevention of bloodstream infection: a systematic review
Data
2016
Tipo
Artigo
Título da Revista
ISSN da Revista
Título de Volume
Resumo
Objective: to evaluate the effectiveness and safety in the use of second-generation central venous catheters impregnated in clorhexidine and silver sulfadiazine when compared with other catheters, being them impregnated or not, in order to prevent the bloodstream infection prevention. Method: systematic review with meta-analysis. Databases searched: MEDLINE, EMBASE, CINAHL, LILACS/SciELO, Cochrane CENTRAL
search in Congress Proceedings and records from Clinical Trials. Results: 1.235 studies were identified, 97 were pre-selected and 4 were included. In catheter-related bloodstream infection, there was no statistical significance between second-generation impregnated catheter compared with the non-impregnated ones, absolute relative risk 1,5% confidence interval 95% (3%-1%), relative risk 0,68 (confidence interval 95%, 0,40-1,15) and number needed to treat 66. In the sensitivity analysis, there was less bloodstream infection in impregnated catheters (relative risk 0,50, confidence interval 95%, 0,26-0,96). Lower colonization, absolute relative risk 9,6% (confidence interval 95%, 10% to 4%), relative risk 0,51 (confidence interval 95% from 0,38-0,85) and number needed to treat 5. Conclusion: the use of second-generation catheters was effective in reducing the catheter colonization and infection when a sensitivity analysis is performed. Future clinical trials are suggested to evaluate sepsis rates, mortality and adverse effects.
search in Congress Proceedings and records from Clinical Trials. Results: 1.235 studies were identified, 97 were pre-selected and 4 were included. In catheter-related bloodstream infection, there was no statistical significance between second-generation impregnated catheter compared with the non-impregnated ones, absolute relative risk 1,5% confidence interval 95% (3%-1%), relative risk 0,68 (confidence interval 95%, 0,40-1,15) and number needed to treat 66. In the sensitivity analysis, there was less bloodstream infection in impregnated catheters (relative risk 0,50, confidence interval 95%, 0,26-0,96). Lower colonization, absolute relative risk 9,6% (confidence interval 95%, 10% to 4%), relative risk 0,51 (confidence interval 95% from 0,38-0,85) and number needed to treat 5. Conclusion: the use of second-generation catheters was effective in reducing the catheter colonization and infection when a sensitivity analysis is performed. Future clinical trials are suggested to evaluate sepsis rates, mortality and adverse effects.
Descrição
Citação
Revista Latino-Americana De Enfermagem. Ribeirao preto, v. 24, p. e2722, 2016.