A new concept for an old instrument: flexible corneal scrapping spatula

dc.contributor.authorLima Filho, Acácio Alves de Souza [UNIFESP]
dc.contributor.authorSchor, Paulo [UNIFESP]
dc.contributor.authorYu, Maria Cecília Zorat [UNIFESP]
dc.contributor.authorHofling-Lima, Ana Luisa [UNIFESP]
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.date.accessioned2015-06-14T13:24:57Z
dc.date.available2015-06-14T13:24:57Z
dc.date.issued1999-12-01
dc.description.abstractWe describe a new methods to produce an instrument to scrap the cornea. It is made from either a fine needle or a cannula. The material is flattened by means of a laminator or a hammer and a flat metal surface. A sandpaper is used to rough the front end and round it. The tip is slightly bent and the device is submitted to ethylene oxide for sterilization. A handle may be used to hold the instrument, which may be reusable, after washing and sterilization using local heat at the tip, or gas.en
dc.description.abstractOs autores descrevem um novo método para produzir um instrumento para colheita de material de córnea. Tal instrumento pode ser manufaturado com uma cânula ou agulha fina. O material é moldado de forma plana com o auxílio de um laminador, ou de um martelo e placa de metal. Lixa fina é utilizada para arredondar as bordas e a ponta é ligeiramente dobrada. Um cabo pode ser adicionado de modo a facilitar a manipulação do instrumento, que pode ser reutilizado após lavagem e esterilização local na ponta do metal, ou por óxido de etileno.pt
dc.description.affiliationFederal University of São Paulo Ophthalmology Department
dc.description.affiliationFederal University of São Paulo Ophthalmology Department Ophthalmos Microbiology Laboratory
dc.description.affiliationUnifespUNIFESP, Ophthalmology Department
dc.description.affiliationUnifespUNIFESP, Ophthalmology Department Ophthalmos Microbiology Laboratory
dc.description.sourceSciELO
dc.format.extent751-753
dc.identifierhttp://dx.doi.org/10.1590/S0004-27491999000600018
dc.identifier.citationArquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 62, n. 6, p. 751-753, 1999.
dc.identifier.doi10.1590/S0004-27491999000600018
dc.identifier.fileS0004-27491999000600018.pdf
dc.identifier.issn0004-2749
dc.identifier.scieloS0004-27491999000600018
dc.identifier.urihttp://repositorio.unifesp.br/handle/11600/866
dc.language.isoeng
dc.publisherConselho Brasileiro de Oftalmologia
dc.relation.ispartofArquivos Brasileiros de Oftalmologia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSpatulaen
dc.subjectMicrobiologyen
dc.subjectDiagnosisen
dc.subjectBioenginee-ringen
dc.subjectCorneaen
dc.subjectEspátulapt
dc.subjectMicrobiologiapt
dc.subjectDiagnósticopt
dc.subjectBioengenhariapt
dc.subjectCórneapt
dc.titleA new concept for an old instrument: flexible corneal scrapping spatulaen
dc.title.alternativeUm novo conceito para um antigo instrumento: espátula corneana flexívelpt
dc.typeinfo:eu-repo/semantics/article