Valor diagnóstico do ultrassom doppler renal versus arteriografia renal em pacientes com estenose da artéria do rim transplantado
Date
2023-03-08Author
Orellana, Henry Campos [UNIFESP]
Advisor
Moisés, Valdir Ambrósio [UNIFESP]Type
Dissertação de mestradoMetadata
Show full item recordAlternative Title
Diagnostic value of doppler ultrasound versus renal arteriography in patients with transplanted renal artery stenosisAbstract
Introdução: Pacientes transplantados renais podem evoluir com disfunção do enxerto cuja principal causa vascular é a estenose da artéria do rim transplantado (EART). A arteriografia do rim transplantado é o padrão ouro para o diagnóstico de EART, porém, o ultrassom doppler renal (USG) é o método de triagem mais utilizado devido ao seu baixo custo, maior disponibilidade e caráter não invasivo. Entretanto o valor diagnóstico desta técnica bem como os critérios que indicam estenose pelo ultrassom são variáveis na literatura.
Objetivos: Analisar o valor diagnóstico da ultrassonografia doppler do rim transplantado no diagnóstico de estenose da artéria renal pela angiografia da artéria renal.
Métodos: Foi um estudo retrospectivo que incluiu pacientes transplantados renais com suspeita clínica de EART que foram submetidos a ultrassonografia e arteriografia renais. Os dados foram obtidos da plataforma REDcap/ EPM que registra os transplantes renais realizados na instituição e dos prontuários eletrônicos dos pacientes. A suspeita clínica de estenose da artéria renal era feita pela evidência de piora da função renal e/ou dos níveis pressóricos no acompanhamento dos pacientes, sendo nestes casos indicados a realização da ultrassonografia renal. A suspeita de EART foi definida pela VPS > 200 cm/s no ultrassom renal e a EART significativa pela redução de 50% ou mais do lúmen arterial na angiografia renal. Os dados foram analisados com estatística descritiva, testes comparativos e de correlação, curva ROC para determinar o valor de corte e estimativa de sensibilidade, especificidade, valores preditivos positivos e negativo e acurácia; significantes se p < 0,05.
Resultados: Dos registros de 6.289 pacientes submetidos a transplante renal na instituição foram inicialmente selecionados 313 pacientes com suspeita clínica e ultrassonográfica de EART, submetidos a arteriografia no Hospital São Paulo, no período de janeiro de 2007 a dezembro de 2014. Destes pacientes, 18 foram excluídos por apresentarem dados incompletos. A velocidade de pico sistólico (VPS) foi significativamente maior nos pacientes com estenose da artéria renal (média 415,3 ± 139 cm/s) do que nos sem estenose (313,4 ± 104,3 cm/s). O ponto de corte da VPS que melhor discriminou a presença de estenose foi de 345 cm/s com sensibilidade de 67,7%, especificidade de 66,7 %, valor preditivo positivo de 88,8%, valor preditivo negativo de 34,5% e uma AUC de 0,67.
Conclusão: A Ultrassonografia Doppler do rim transplantado, comparado com a angiografia, representa um método diagnóstico adicional de triagem com boa acurácia para o diagnóstico de estenose de artéria renal. O valor da velocidade de pico sistólico de 345 cm/s que melhor discriminou o diagnóstico de estenose da artéria renal pela angiografia foi significativamente superior ao valor de 200 cm/s que é o mais utilizado na literatura. Background: kidney transplant patients, can evolve with graft dysfunction, whose main
vascular cause is the stenosis of the transplanted renal artery (TRAS). Arteriography of
the transplanted kidney is the gold standard for the diagnosis of TRAS, however, Renal
Doppler Ultrasound (DUS) is the most used screening method, due to its low cost, greater
availability and non-invasive character. However, the diagnostic value of this technique,
as well as the criteria that indicate stenosis by ultrasound, are variable in the literature.
Objectives: To analyze the diagnostic value of doppler ultrasonography of the transplant
kidney in the diagnosis of renal artery stenosis by renal artery angiography.
Methods: This was a retrospective study that included renal transplant patients with
clinical suspicion of TRAS who underwent renal ultrasound and arteriography. Data were
obtained from the Redcap/EPM platform that records kidney transplants performed at the
institution and from the patients’ electronic medical records. Clinical suspicion of renal
artery stenosis was based on evidence of worsening renal function and/or blood pressure
levels during patient follow-up, in which case renal ultrasonography was indicated.
Suspicion of TRAS was defined by PSV > 200 cm/s on renal ultrasound and significant
TRAS by reduction of 50% or more in the arterial lumen on renal angiography. Data were
analyzed using descriptive statistics, comparative and correlation tests, ROC curve to
determine the cut-off value and estimation of sensitivity, specificity, positive and negative
predictive values and accuracy; significant if p < 0,05.
Results: From the records of 6.289 patients undergoing kidney transplantation at the
institution, 313 patients with clinical and ultrasonographic suspicion of EART, who
underwent arteriography at Hospital São Paulo, from January 2007 to December 2014.
Of these patients, 18 were excluded for presenting incomplete data. The peak systolic
velocity (PSV) was significantly higher in patients with renal artery stenosis (mean 415.3
± 139 cm/s) than in those without stenosis (313,4 ± 104,3 cm/s). The PSV cutoff point that
best discriminated the presence of stenosis was 345 cm/s with a sensitivity of 67,7%
specificity of 66,7%, positive predictive value of 88,8%, negative predictive value of 34,5%
and an AUC of 0,67.
Conclusion: Doppler ultrasonography of the transplanted kidney, compared to
angiography, represents and additional diagnostic screening method with good accuracy
for the diagnostic of renal artery stenosis. The systolic peak velocity value of 345 cm/s
that best discriminated the diagnosis of renal artery stenosis by angiography was
significantly higher than the value of 200cm/s, which is the most used in the literature.
Keywords
Estenose de artéria renalTransplante renal
Ultrassom doppler renal
Velocidade de pico sistólica
Collections
Related items
Showing items related by title, author, creator and subject.
-
Estudo de parâmetros de função renal e vesical em pacientes com bexiga neurogênica por mielomeningocele com lesão renal detectada por cintilografia renal com DMSA e submetidos à análise de marcadores séricos e urinários do sistema renina angiotensina aldosterona
Amaral, Cassia Maria Carvalho Abrantes Do [UNIFESP] (Universidade Federal de São Paulo (UNIFESP), 2019-06-14)Introduction: Myelomeningocele (MMC) is defined as a malformation of the central nervous system caused by a failed closure of the neural tube in the embryonic period. MMC is mainly associated with nephrological manifestations ...
-
A rare case of TFE-related pigmented renal tumor with overlapping features between melanotic Xp11 translocation renal cancer and Xp11 renal cell carcinoma with melanotic features
Cardili, Leonardo [UNIFESP]; Pereira, Gregorio Wrublevsky; Viana, Cristiano Ribeiro (Wiley, 2017)In recent years, an increasing number of TFE3 rearrangement-associated tumors with melanotic features have been reported as primary neoplasm in different anatomical sites, including the kidney. Melanotic Xp11 translocation ...
-
Is hepatitis C more aggressive in renal transplant patients than in patients with end-stage renal disease?
Perez, R. M.; Ferreira, ASP; Medina-Pestana, J. O.; Cendoroglo Neto, Miguel [UNIFESP]; Lanzoni, V. P.; Silva, AEB; Ferraz, MLG (Lippincott Williams & Wilkins, 2006-05-01)Background: the eventual impact of immunosuppression on the natural history of hepatitis C virus (HCV) infection in patients with end-stage renal disease (ESRD) is still unknown because of the lack of comparative data for ...