Application of different scheimpflug-based lens densitometry methods in phacodynamics prediction

Nenhuma Miniatura disponível
Data
2016
Autores
Faria-Correia, Fernando
Lopes, Bernardo T.
Ramos, Isaac C.
Monteiro, Tiago
Franqueira, Nuno
Ambrosio, Renato, Jr. [UNIFESP]
Orientadores
Tipo
Artigo
Título da Revista
ISSN da Revista
Título de Volume
Resumo
Purpose: To evaluate the correlations between preoperative Scheimpflug-based lens densitometry metrics and phacodynamics. Methods: The Lens Opacities Classification System III (LOCS III) was used to grade nuclear opalescence (NO), along with different methods of lens densitometry evaluation (absolute scale from 0% to 100%): three-dimensional (3D), linear, and region of interest (l)l modes. Cumulative dissipated energy (CDE) and total ultrasound (US) time were recorded and correlated with the different methods of cataract grading. Significant correlations were evaluated using Pearson or Spearman correlation coefficients according to data normality. Results: A positive correlation was detected between the NO score and the average density and the maximum density derived from the 3D mode (r-0.624, P<0.001
r=0.619, P<0.001, respectively) and the ROI mode (r=0.600, P<0.001
r=0.642, P<0.001, respectively). Regarding the linear mode, only the average density parameter presented a significant relationship with the NO score (r=0.569, P<0.001 I. The 3D-derived average density and maximum density were positively correlated with CDE (rho=0.682, P<0.001
rho=0.683, P<0.001, respectively) and total US tune (rho=0.631 and rho=0.668, respectively). There was a linear relationship between the average density and maximum density of the ROI mode and CDI (rho=0.686, P<0.001
rho=0.598, P<0.001, respectively) and total US time (rho=0.642 and rho=0.644, respectively). The average density was the only parameter derived from the linear mode that showed a significant correlation with. CDI (rho =0.522, P<0.001) and total US time (rho =0.450, P<0.001). Conclusion: Specific Scheimpflug-derived densitometric parameters of the nucleus correlated with phacoemulsification parameters. The use of the appropriate densitometry approach can predict more efficiently the phacodynamics.
Descrição
Citação
Clinical Ophthalmology. Albany, v. 10, p. 609-615, 2016.