Comparison of Methodologies in Volumetric Orbitometry

Thumbnail
Date
2013-11-01
Author
Osaki, Tammy H. [UNIFESP]
Castro, Dawn K. de
Yabumoto, Cristina [UNIFESP]
Mingkwansook, Varalee
Ting, Eric
Nallasamy, Nambi
Curtin, Hugh
Fay, Aaron
Type
Artigo
ISSN
0740-9303
Is part of
Ophthalmic Plastic and Reconstructive Surgery
DOI
10.1097/IOP.0b013e31829d028a
Metadata
Show full item record
Abstract
Purpose: the rate at which the orbit matures is not well-documented. Limiting this pursuit are the difficulties inherent in measuring orbital volumes accurately. This study compared 3 common methods of determining orbital volume and sought to identify an accurate, practical manner for doing so.Methods: the volume of 1 orbit of 8 human cadaver heads was independently measured using 3 different methods: 1) CT was performed, and images were analyzed with 3-dimensional (3D) volumetric software; 2) the same orbits were then exenterated and a silicone cast was taken. the cast volumes were measured by water displacement; 3) the orbits were then filled with 1-mm glass beads that were transferred to a graduated cylinder where their volume was determined. the data were analyzed statistically.Results: Intraobserver agreements were good for both beads and casts. Interobserver agreements were good for both beads and CT (p > 0.05). Values obtained using the bead method were equal to values obtained using the cast method (p > 0.05). However, agreement between direct (orbital fillers and casts) and indirect measurements (radiographic techniques) was not satisfactory (p < 0.05).Conclusions: Independent of method, determining orbital volume is inherently difficult owing to the hyperbolic parabola that is the orbit entrance; all methods require estimation. Glass beads and casts yielded more reproducible values but can only be used in cadavers. CT measurement is prone to error due to the variability of methodologies used but allows access to enormous testing populations. Interstudy comparison is currently not possible. CT volumetric software with strict universal standards for estimating the anterior limit of the orbit appears to be the best method of studying human orbital volumes.
Citation
Ophthalmic Plastic and Reconstructive Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 29, n. 6, p. 431-436, 2013.
Sponsorship
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Pan American Ophthalmological Foundation
Retina Research Foundation
URI
http://repositorio.unifesp.br/handle/11600/36962
Collections
  • EPM - Artigos [17701]

DSpace software copyright © 2002-2016  DuraSpace
Contact Us
Theme by 
Atmire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy Submit DateThis CollectionBy Issue DateAuthorsTitlesSubjectsBy Submit Date

My Account

Login

Statistics

View Usage Statistics

DSpace software copyright © 2002-2016  DuraSpace
Contact Us
Theme by 
Atmire NV