Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/55011
Title: Comparison Between Spectral-Domain and Swept-Source Optical Coherence Tomography Angiographic Imaging of Choroidal Neovascularization
Authors: Miller, Andrew R.
Roisman, Luiz [UNIFESP]
Zhang, Qinqin
Zheng, Fang
Dias, Joao Rafael de Oliveira
Yehoshua, Zohar
Schaal, Karen B.
Feuer, William
Gregori, Giovanni
Chu, Zhongdi
Chen, Chieh-Li
Kubach, Sophie
An, Lin
Stetson, Paul F.
Durbin, Mary K.
Wang, Ruikang K.
Rosenfeld, Philip J.
Keywords: optical coherence tomography angiography
OCTA
swept-source OCTA
spectral-domain OCTA
neovascular AMD
choroidal neovascularization
Issue Date: 2017
Publisher: Assoc Research Vision Ophthalmology Inc
Citation: Investigative Ophthalmology & Visual Science. Rockville, v. 58, n. 3, p. 1499-1505, 2017.
Abstract: PURPOSE. The purpose of this study was to compare imaging of choroidal neovascularization (CNV) using swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA). METHODS. Optical coherence tomography angiography was performed using a 100-kHz SS-OCT instrument and a 68-kHz SD-OCTA instrument (Carl Zeiss Meditec, Inc.). Both 3 x 3-and 6 x 6-mm(2) scans were obtained on both instruments. The 3 x 3-mm(2) SS-OCTA scans consisted of 300 A-scans per B-scan at 300 B-scan positions, and the SD-OCTA scans consisted of 245 A-scans at 245 B-scan positions. The 6 x 6-mm(2) SS-OCTA scans consisted of 420 A-scans per B-scan at 420 B-scan positions, and the SD-OCTA scans consisted of 350 A-scans and 350 B-scan positions. B-scans were repeated four times at each position in the 3 x 3-mm(2) scans and twice in the 6 x 6-mm(2) scans. Choroidal neovascularization was excluded if not fully contained within the 3 x 3-mm(2) scans. The same algorithm was used to detect CNV on both instruments. Two graders outlined the CNV, and the lesion areas were compared between instruments. RESULTS. Twenty-seven consecutive eyes from 23 patients were analyzed. For the 3 x 3-mm(2) scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.17 and 1.01 mm(2), respectively (P = 0.047). For the 6 x 6-mm(2) scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.24 and 0.74 mm(2) (P = 0.003). CONCLUSIONS. The areas of CNV tended to be larger when imaged with SS-OCTA than with SD-OCTA, and this difference was greater for the 6 x 6-mm(2) scans.
URI: https://repositorio.unifesp.br/handle/11600/55011
ISSN: 0146-0404
Other Identifiers: http://dx.doi.org/10.1167/iovs.16-20969
Appears in Collections:Artigo

Files in This Item:
File SizeFormat 
WOS000398089000018.pdf1.23 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.