Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/51246
Title: Novel immunoassay for TSH measurement in rats
Authors: Alves, Thalita G. [UNIFESP]
Melo, Maria Clara de C. [UNIFESP]
Kasamatsu, Teresa S. [UNIFESP]
Oliveira, Kelen C. [UNIFESP]
de Souza, Janaina Sena [UNIFESP]
da Conceicao, Rodrigo Rodrigues [UNIFESP]
Giannocco, Gisele [UNIFESP]
Dias-da-Silva, Magnus R. [UNIFESP]
Chiamolera, Maria Izabel [UNIFESP]
Vieira, Jose Gilberto [UNIFESP]
Keywords: Immunoassay
rats
TSH
Issue Date: 2017
Publisher: Sbem-Soc Brasil Endocrinologia & Metabologia
Citation: Archives Of Endocrinology Metabolism. Rio De Janeiro, Rj, v. 61, n. 5, p. 460-463, 2017.
Abstract: Measuring thyroid hormones is an important aspect for the study of metabolism and for monitoring diseases in both human and animal models. The traditional method for hormone measurement in rats is the radioimmunoassay (RIA). However, the RIA is associated with some practical disadvantages, including the use of radioactive material, the need for specialized equipment and expert staff, the short shelf-life of kits according to the half-life of the radioisotope and high costs. The objective of this study was to develop a new cost-effective method for measuring TSH levels in rats that avoids the use of radioactive material. We developed an in-house competitive immunoassay using a reference standard, polyclonal antibody produced in rabbits and biotinylated antigen. This method was tested in 64 Wistar rats that were divided into a control group (n = 41) and a group with hypothyroidism (n = 23). Our assay demonstrated an analytical sensitivity of 0.24 ng/mL (n = 12) and an intra-assay coefficient of variation (CV) of 8.9% for sera with TSH levels of 1.5 ng/mL and 13.2% for sera with TSH levels of 17.5 ng/mL (n = 14). The inter-assay CV was 13.5% for sera with TSH levels of 1.4 ng/mL and 14.5% for TSH levels of 18.2 ng/mL (n = 5). The analysis of mean TSH levels in control rats (5.06 +/- 0.5701) and hypothyroid rats (51.09 +/- 5.136) revealed a statistically significant difference (p < 0.001) between the groups. This method showed good sensitivity, can be automated and is low-cost compared with RIA. Our method offers a viable alternative for TSH measurement in rats.
URI: http://repositorio.unifesp.br/handle/11600/51246
ISSN: 2359-3997
Other Identifiers: http://dx.doi.org/10.1590/2359-3997000000293
Appears in Collections:Artigo
Artigo

Files in This Item:
File SizeFormat 
WOS000416002900009.pdf94.74 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.