Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/34286
Title: Constant Work-Rate Test to Assess the Effects of Intradialytic Aerobic Training in Mildly Impaired Patients With End-Stage Renal Disease: A Randomized Controlled Trial
Authors: Reboredo, Maycon M.
Neder, J. Alberto [UNIFESP]
Pinheiro, Bruno V.
Henrique, Diane M.
Faria, Ruiter S.
Paula, Rogerio B.
Univ Fed Juiz de Fora
Fed Inst Educ Sci & Technol SE Minas Gerais
Universidade Federal de São Paulo (UNIFESP)
Keywords: Exercise
Exercise tolerance
Kidney failure
chronic
Rehabilitation
Issue Date: 1-Dec-2011
Publisher: Elsevier B.V.
Citation: Archives of Physical Medicine and Rehabilitation. Philadelphia: W B Saunders Co-Elsevier Inc, v. 92, n. 12, p. 2018-2024, 2011.
Abstract: Objective: To investigate if high-intensity constant work rate (CWR) would constitute a more appropriate testing strategy compared with incremental work rate (IWR) to assess the effectiveness of intradialytic aerobic training in patients with end-stage renal disease (ESRD).Design: Randomized controlled trial.Setting: Nephrology unit at the university hospital.Participants: Patients (N=28; 47.0 +/- 11.9y) under hemodialysis (4.4 +/- 4.3y) were randomly assigned to exercise and control groups.Intervention: Patients included in the exercise group underwent a moderate-intensity intradialytic aerobic training program 3 times per week for 12 weeks.Main Outcome Measures: Cardiopulmonary and perceptual responses were obtained during an IWR and a high-intensity CWR test to the limit of tolerance on a cycle ergometer.Results: Training-induced increases in peak oxygen uptake (Vo(2)peak) and time to exercise intolerance (Tlim). Mean improvement in Tlim (97.4%+/- 75.6%) was significantly higher than increases in Vo(2)peak (12%+/- 11.3%) (P<.01); in fact, while Tlim improved 50% to 200% in 9 of 12 patients, Vo(2)peak increases were typically in the 15% to 20% range. CWR test revealed lower metabolic, ventilatory, cardiovascular, and subjective stresses at isotime; in contrast, submaximal responses during the incremental work rate (at the gas exchange threshold) remained unaltered after training.Conclusions: A laboratory-based measure of endurance exercise capacity (high-intensity CWR test to Thin) was substantially more sensitive than oxygen uptake at the peak IWR test to unravel the physiologic benefits of an intradialytic aerobic training program in mildly impaired patients with ESRD.
URI: http://repositorio.unifesp.br/handle/11600/34286
ISSN: 0003-9993
Other Identifiers: http://dx.doi.org/10.1016/j.apmr.2011.07.190
Appears in Collections:Em verificação - Geral

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.