Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/32905
Title: Biomechanical and Tomographic Analysis of Unilateral Keratoconus
Authors: Fontes, Bruno M. [UNIFESP]
Ambrosio, Renato
Salomao, Marcella
Velarde, Guillermo C.
Nose, Walton [UNIFESP]
Universidade Federal de São Paulo (UNIFESP)
REFRACTA RIO
Renato Ambrosio Eye Inst
Benjamin Constant Inst
Universidade Federal Fluminense (UFF)
Issue Date: 1-Sep-2010
Publisher: Slack Inc
Citation: Journal of Refractive Surgery. Thorofare: Slack Inc, v. 26, n. 9, p. 677-681, 2010.
Abstract: PURPOSE: To evaluate and compare tomographic, clinical, and biomechanical data of patients with unilateral keratoconus and healthy controls.METHODS: Observational, case-control study. Complete clinical eye examination was followed by topographic (ATLAS), tomographic (Pentacam), and biomechanical (Ocular Response Analyzer) evaluation. Cases were sex-and age-matched with healthy individuals for controls.RESULTS: Four patients had unilateral keratoconus, and eight healthy patients served as controls. Central corneal thickness was 508 +/- 16 mu m in the keratoconus group, 531 +/- 12.7 mu m in the fellow eye group, and 528.6 +/- 40.7 mu m in the control group (P > .125, all comparisons). Central keratometry was 43.70 +/- 2.70 diopters (D) in the keratoconus group, 42.84 +/- 1.43 D in the fellow eye group, and 43.81 +/- 1.94 D in the control group (P > .45, all comparisons). Corneal astigmatism was 3.30 +/- 2.24 D in the keratoconus group, 1.38 +/- 1.49 D in the fellow eye group, and 1.34 +/- 1.13 D in the control group (P =. 037 between the keratoconus and control groups; P =. 25 between the keratoconus and fellow eye groups). Corneal hysteresis was 8.13 +/- 2 mmHg in the keratoconus group, 8.96 +/- 0.86 mmHg in the fellow eye group, and 9.89 +/- 1.33 mmHg in the control group (P > .064, all comparisons). Corneal resistance factor was 7.96 +/- 2.43 mmHg in the keratoconus group, 8.92 +/- 1.39 mmHg in the fellow eye group, and 9.90 +/- 2.24 mmHg in the control group (P > .33, all comparisons).CONCLUSIONS: Corneal hysteresis and corneal resistance factor values were not statistically different among the groups; however, a trend for lower values was found for keratoconus and fellow eyes compared to controls. Data should be interpreted with caution because of the small sample. [J Refract Surg. 2010; 26(9): 677-681.] doi:10.3928/1081597X-20091105-04
URI: http://repositorio.unifesp.br/handle/11600/32905
ISSN: 1081-597X
Other Identifiers: http://dx.doi.org/10.3928/1081597X-20091105-04
Appears in Collections:Em verificação - Geral

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.