Please use this identifier to cite or link to this item: https://repositorio.unifesp.br/handle/11600/32896
Title: Non-urgent caesarean delivery increases the need for ventilation at birth in term newborn infants
Authors: Branco de Almeida, Maria Fernanda [UNIFESP]
Guinsburg, Ruth [UNIFESP]
Costa, Jose Orleans da
Anchieta, Leni Marcia
Silveira Freire, Lincoln Marcelo
Campos, Dioclecio
Universidade Federal de São Paulo (UNIFESP)
Brazilian Pediat Soc
Med Sch Barbacena
Universidade Federal de Minas Gerais (UFMG)
Universidade de Brasília (UnB)
Issue Date: 1-Sep-2010
Publisher: B M J Publishing Group
Citation: Archives of Disease in Childhood-fetal and Neonatal Edition. London: B M J Publishing Group, v. 95, n. 5, p. F326-F330, 2010.
Abstract: Objective To compare the need for positive pressure ventilation (PPV) by bag and mask and by bag and endotracheal tube in newly born term infants with vertex presentation delivered by non-urgent caesarean section under regional anaesthesia or non-instrumental vaginal delivery.Design Cross-sectional study.Setting 35 public hospitals in 20 Brazilian state capitals.Patients 6929 inborn infants without congenital anomalies, with gestational ages from 37(0/7) to 41(6/7) weeks with vertex presentation, born between 1 and 30 September 2003.Intervention Non-urgent caesarean versus non-instrumental vaginal delivery. Non-urgent caesarean was defined as delivery occurring in the absence of prolapsed cord, third trimester haemorrhage, failure of labour induction, fetal distress or non-clear amniotic fluid.Main outcome measures PPV with bag and mask and with bag and endotracheal tube. Both outcomes were adjusted for potential confounding variables by logistic regression analysis.Results 2087 infants were born by non-urgent caesarean and 4842 by non-instrumental vaginal delivery. Non-urgent caesarean delivery under regional anaesthesia compared to vaginal delivery under local or no anaesthesia increased the risk of bag and mask ventilation (OR 1.42, 95% Cl 1.07 to 1.89) adjusted for number of gestations, maternal hypertension and birth weight. Ventilation with bag and endotracheal tube was associated only with low birth weight, adjusted for delivery mode and twin gestation.Conclusions Term neonates with vertex presentation and clear amniotic fluid born by non-urgent caesarean section under regional anaesthesia need to be assisted at birth by health professionals skilled in PPV.
URI: http://repositorio.unifesp.br/handle/11600/32896
ISSN: 1359-2998
Other Identifiers: http://dx.doi.org/10.1136/adc.2009.174532
Appears in Collections:Em verificação - Geral

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.