Title: Comparative study of coaxial phacoemulsification and microincision cataract surgery - One-year follow-up
Authors: Crema, Armando Stefano
Walsh, Aileen
Yamane, Yoshifumi
Nose, Walton
Univ Gama Filho
Universidade Federal de São Paulo (UNIFESP)
Issue Date: 1-Jun-2007
Publisher: Elsevier B.V.
Citation: Journal of Cataract and Refractive Surgery. New York: Elsevier B.V., v. 33, n. 6, p. 1014-1018, 2007.
Abstract: PURPOSE: To evaluate the amount of ultrasound (US) used, best corrected visual acuity (BCVA), and corneal endothelial cell loss in bimanual microincision cataract surgery (MICS) and coaxial phacoemulsification.SETTING: Department of Ophthalmology, Universiclade Gama Filho, Rio de Janeiro, Brazil.METHODS: A prospective randomized study included 30 patients (60 eyes) with bilateral cataract. All patients had coaxial phacoemulsification in 1 eye and MICS in the fellow eye. the US time and the effective US time were measured intraoperatively. the BCVA and central endothelial cell loss were evaluated in both groups over a 1-year follow-up. the results between the 2 groups were compared.RESULTS: the total US time was lower in the coaxial phacoemulsification group than in the MICS group; the means were 0.50 minutes +/- 0.33 (SD) and 0.82 +/- 0.39 minutes, respectively. the mean US power was similar between groups (mean 10.1 % +/- 3.76% and 10.0% +/- 4.0%, respectively). the BCVA was similar between the groups from 24 hours to 1 year. the mean central corneal enclothelial cell loss at 3 months was 4.66% +/- 6.10% in the coaxial phacoemulsification group and 4.45% +/- 5.06% in the MICS group and at 1 year, 6.00% +/- 6.72% and 8.82% +/- 7.39%, respectively. the only significant difference in the postoperative results between the 2 groups was central endothelial cell loss at the 1-year follow-up.CONCLUSIONS: the US time was longer in the MICS group than in the in the coaxial phacoemulsification group, but the mean US power was similar between groups. the BCVA was also similar between groups; however, the MICS group had more central enclothelial cell loss atthe 1-year follow-up.
URI: http://repositorio.unifesp.br/handle/11600/29801
ISSN: 0886-3350
Other Identifiers: http://dx.doi.org/10.1016/j.jcrs.2007.02.035
Appears in Collections:Em verificação - Geral

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.