Replacement of infected thoracic aortic prosthesis with a spiral composite vein graft

Replacement of infected thoracic aortic prosthesis with a spiral composite vein graft

Autor Fonseca, José Honório Palma da Autor UNIFESP Google Scholar
Gomes, Walter J. Autor UNIFESP Google Scholar
Almeida, Dirceu R. Autor UNIFESP Google Scholar
Carvalho, Antonio C. Autor UNIFESP Google Scholar
Brasil, Luiz A. Autor UNIFESP Google Scholar
Buffolo, Enio Autor UNIFESP Google Scholar
Instituição Universidade Federal de São Paulo (UNIFESP)
Resumo We describe a case of a patient who had a ruptured aorta repaired by femorofemoral bypass with an interposition graft and subsequently had a graft infection. the patient was taken to operation and the old graft was removed. It was replaced by a spiral great saphenous vein graft. the patient has been followed up for 36 months with computed tomographic scanning, which has shown that the vein graft has not dilated. (C) 1998 by the Society of Thoracic Surgeons.
Idioma Inglês
Data 1998-04-01
Publicado em Annals of Thoracic Surgery. New York: Elsevier B.V., v. 65, n. 4, p. 1135-1137, 1998.
ISSN 0003-4975 (Sherpa/Romeo, fator de impacto)
Editor Elsevier B.V.
Extensão 1135-1137
Fonte http://dx.doi.org/10.1016/S0003-4975(98)00049-6
Direito de acesso Acesso aberto Open Access
Tipo Editorial
Web of Science WOS:000073160100055
URI http://repositorio.unifesp.br/handle/11600/25880

Mostrar registro completo




Arquivos deste item

Arquivos Tamanho Formato Visualização

Não existem arquivos associados a este item.

Este item aparece na(s) seguinte(s) coleção(s)