Evaluation of two 99mTc-DTPA radioaerosols with different characteristics in lung ventilation studies

Evaluation of two 99mTc-DTPA radioaerosols with different characteristics in lung ventilation studies

Autor Silveira, C.m. Autor UNIFESP Google Scholar
Castiglioni, M.l.v. Autor UNIFESP Google Scholar
Torres, I.c.g. Autor UNIFESP Google Scholar
Medeiros, Regina Bitelli Autor UNIFESP Google Scholar
Jardim, José Roberto Autor UNIFESP Google Scholar
Instituição Universidade Federal de São Paulo (UNIFESP)
Resumo Two radioaerosol preparations, TechneScan®-DTPA (99mTc-DTPA, 40 mCi/3 ml; IPEN-CNEN, São Paulo, SP, Brazil) and TechneScan®-DTPA/AEROSOL (99mTc-DTPA/A, 15 mCi/1.5 ml with 0.5 ml ethanol; Mallinckrodt Medical, St. Louis, MO, USA), were compared in pulmonary ventilation studies in terms of total radiocounts and clearance after inhalation. An aerosol with ethanol is supposed to better distribute the radioparticles in the lungs. Twenty normal nonsmoking volunteers (10 men and 10 women), mean age of 23.2 years (range: 20 to 35 years), were studied. Images were obtained immediately and 30, 60 and 90 min after inhalation. Total and regional counts were obtained and the clearance half-lives of both lungs were determined. There was no difference in total counts between the two types of radioaerosol at any time (mean of ~188,000 cpm for male and female subjects at time zero in both aerosols). The highest count was obtained in the middle region of both lungs (P<0.001) with both preparations. The clearance half-life did not differ between aerosols (mean of ~80-88 min for male and female subjects for both aerosols). Small nonsignificant regional differences were observed. No differences between genders or between right and left lung were observed. 99mTc-DTPA/A generated the highest output of radioaerosol. 99mTc-DTPA with alcohol costs approximately five times more than the aerosol without alcohol. The present results show that either kind of aerosol may be adopted routinely for use in pulmonary examinations without affecting diagnosis. We suggest that the amount of 740 mBq (20 mCi) of 99mTc-DTPA in 1.5 ml saline can be used for routine examinations resulting in reduction of costs in pulmonary ventilation studies without diagnostic impairment.
Palavra-chave Pulmonary ventilation
Pulmonary clearance
Radioaerosol
99mTc-DTPA
Idioma Inglês
Data de publicação 2003-10-01
Publicado em Brazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 36, n. 10, p. 1333-1340, 2003.
ISSN 0100-879X (Sherpa/Romeo, fator de impacto)
Publicador Associação Brasileira de Divulgação Científica
Extensão 1333-1340
Fonte http://dx.doi.org/10.1590/S0100-879X2003001000009
Direito de acesso Acesso aberto Open Access
Tipo Artigo
Web of Science WOS:000185906900010
SciELO S0100-879X2003001000009 (estatísticas na SciELO)
Endereço permanente http://repositorio.unifesp.br/handle/11600/1886

Exibir registro completo




Arquivo

Nome: S0100-879X2003001000009.pdf
Tamanho: 653.5KB
Formato: PDF
Descrição:
Abrir arquivo

Este item está nas seguintes coleções

Buscar


Navegar

Minha conta